Five-hole probes need calibration because their five ports sense pressure. Calibration relationships are needed to turn those readings into flow velocity, direction, and other relevant parameters. Having five sensing locations does not, on its own, tell you what flow condition a set of pressures represents. WINDTUNER offers custom five-hole probes and probe calibration services to establish a suitable basis for measurements under the flow conditions expected in development tests.
Relating pressure differences to flow direction
A five-hole probe typically has four directional ports around a center port. As the flow turns relative to the head, the pressure responses at these locations change. Comparing pressures in two perpendicular planes provides information about the flow angle in each direction. To convert the differences into angles, however, the response of that head under the relevant conditions must be known.
Calibration establishes that relationship. The head is placed in airflow under known conditions, its angle to the flow is varied according to the calibration plan, and the port pressures are recorded. Those measurements link the pressure responses to the angles. During a test, the system uses calibration data appropriate to the probe, together with the acquired pressures, to calculate the parameters. Engineers can then relate the pressure readings to flow direction at the measurement point.

Calibration establishes that relationship. The head is placed in airflow under known conditions, its angle to the flow is varied according to the calibration plan, and the port pressures are recorded. Those measurements link the pressure responses to the angles. During a test, the system uses calibration data appropriate to the probe, together with the acquired pressures, to calculate the parameters. Engineers can then relate the pressure readings to flow direction at the measurement point.
Similar heads still need suitable calibration data
Head shape, port orientation, and dimensions affect the pressure distribution as air passes over a probe. Two probes looking alike is not sufficient reason to use the same calibration data for both. With a custom probe in particular, the calibration relationships need to be matched to its actual geometry and intended measurement task.
WINDTUNER can customize pneumatic probes by material, shape, port count, port diameter, head size, stem, and mounting arrangement. Customization addresses how the head fits the test location and operating conditions. Calibration provides the basis for converting pressure into flow parameters. Discussing geometry and calibration together helps define the intended measurement range before manufacture and delivery.
The calibration conditions also need to cover the flow range planned for the test. Speed and flow angle affect the head response, so the calibration should suit those requirements. Data obtained for a probe under specified conditions cannot simply be extended to every speed and angle. Describe the expected flow and required parameters first, then confirm the probe and calibration plan.
WINDTUNER can customize pneumatic probes by material, shape, port count, port diameter, head size, stem, and mounting arrangement. Customization addresses how the head fits the test location and operating conditions. Calibration provides the basis for converting pressure into flow parameters. Discussing geometry and calibration together helps define the intended measurement range before manufacture and delivery.
The calibration conditions also need to cover the flow range planned for the test. Speed and flow angle affect the head response, so the calibration should suit those requirements. Data obtained for a probe under specified conditions cannot simply be extended to every speed and angle. Describe the expected flow and required parameters first, then confirm the probe and calibration plan.
Using calibration data in a test
Five-hole probe measurements involve the head, pressure acquisition equipment, and data processing. The head senses pressure at its ports, the acquisition equipment records the signals, and measurement and control software applies the calibration data using the appropriate calculation configuration. WINDTUNER offers probes, pressure scanners, and measurement and control equipment. The connections and calculation functions should be confirmed for the test task.
Before taking measurements, check that the calibration data correspond to the actual probe. Installation orientation and angle definitions also need to follow the conventions used during calibration so that the calculated flow angles have a clear physical meaning. If the head is deformed, damaged, or modified, reassess whether the original relationships still apply. Continuing pressure readings alone are not evidence that the calibration remains valid.
Calibrating the pressure scanner cannot replace pneumatic probe calibration. Scanner calibration concerns how accurately the equipment measures an input pressure. Probe calibration concerns the relationship between flow parameters and the pressures sensed by the head. Both are needed to make use of the pressure information in flow analysis.
Five-hole probe calibration gives calculated velocity and flow direction a basis in measurement. Tell WINDTUNER the target conditions, head dimensions, and installation location to discuss manufacture, calibration, and use of the data together. For development testing, this addresses more of the actual measurement task than simply confirming that all five ports deliver pressure readings. It also supports comparisons of local flow under different test conditions.

Before taking measurements, check that the calibration data correspond to the actual probe. Installation orientation and angle definitions also need to follow the conventions used during calibration so that the calculated flow angles have a clear physical meaning. If the head is deformed, damaged, or modified, reassess whether the original relationships still apply. Continuing pressure readings alone are not evidence that the calibration remains valid.
Calibrating the pressure scanner cannot replace pneumatic probe calibration. Scanner calibration concerns how accurately the equipment measures an input pressure. Probe calibration concerns the relationship between flow parameters and the pressures sensed by the head. Both are needed to make use of the pressure information in flow analysis.
Five-hole probe calibration gives calculated velocity and flow direction a basis in measurement. Tell WINDTUNER the target conditions, head dimensions, and installation location to discuss manufacture, calibration, and use of the data together. For development testing, this addresses more of the actual measurement task than simply confirming that all five ports deliver pressure readings. It also supports comparisons of local flow under different test conditions.