A 3D flow measurement system brings pneumatic probes, acquisition equipment, motion control, and measurement and control software together. It measures flow parameters at selected points and links the results to their positions. In development tests covering several locations, knowing where a reading was taken is as important as knowing the flow conditions there. WINDTUNER can configure the equipment around the test so that probe movement, pressure acquisition, and data recording work in the required sequence.

Define the Measurement Locations
Before the test, plan the measurement points around the dimensions of the model or test section and define the coordinate directions. Point count, spacing, and probe access affect the movement path and sampling plan. Consistent coordinates and parameter definitions make it easier to compare operating conditions without confusing a change in flow with a change in measurement position.
A five-hole probe can measure velocity and flow angles at one point. To examine the distribution across a whole test section, move the probe to different locations, collect data at each one, and associate the results with their positions. The number and spacing of points, and the area to be covered, should follow the test objective and the time available.
A five-hole probe can measure velocity and flow angles at one point. To examine the distribution across a whole test section, move the probe to different locations, collect data at each one, and associate the results with their positions. The number and spacing of points, and the area to be covered, should follow the test objective and the time available.
Move the Probe into Position
WINDTUNER's motorized traverse systems work with motion controllers to move mounted pneumatic probes and other sensing components. Translation stages change position, while rotary stages adjust the relevant orientation. The arrangement depends on the test. Consider travel, installation space, and load requirements, and check that the tip and stem will not collide with the model or other components along the path.
WindLabX measurement and control software can work with the motion equipment to control positioning. A point-by-point test needs a defined sequence for reaching a location, meeting the sampling conditions, and recording data. The wait before sampling and the recording duration depend on flow stability, tubing, and the measurement task. Stage speed alone does not determine how long the test will take.

WindLabX measurement and control software can work with the motion equipment to control positioning. A point-by-point test needs a defined sequence for reaching a location, meeting the sampling conditions, and recording data. The wait before sampling and the recording duration depend on flow stability, tubing, and the measurement task. Stage speed alone does not determine how long the test will take.
Record the Probe's Pressure Responses
Tubing connects the pneumatic probe's ports to a pressure scanner, which records pressure on each channel. Software then processes the signals using the probe's calibration data and the appropriate calculations to obtain pressure, velocity, or flow-direction information. Confirm the port-to-channel assignments and check that the tubing connections and calibration data suit the test.
Probe and acquisition choices vary with the measurements needed. A total-pressure-only test may call for total pressure probes. Measuring three-dimensional flow direction requires suitable multi-hole probes and calibration coverage. If temperature is also needed, the relevant temperature acquisition equipment can be added. Instruments that do not serve the task need not be included in every system.
Probe and acquisition choices vary with the measurements needed. A total-pressure-only test may call for total pressure probes. Measuring three-dimensional flow direction requires suitable multi-hole probes and calibration coverage. If temperature is also needed, the relevant temperature acquisition equipment can be added. Instruments that do not serve the task need not be included in every system.
Keep Data Linked to Position
WindLabX measurement and control software provides equipment management, data acquisition, storage and viewing, and parameter settings. It supports networked instruments in a distributed data acquisition system, giving the test team a common interface for equipment connections and recording. Position records, sampling sequences, and processing requirements need to be confirmed for the project configuration.
Results from several points should be traceable to their coordinates and test conditions. Pressure curves or velocity readings without position information are difficult to use for examining a test-section distribution. Keep the necessary probe, calibration, and acquisition settings with the results. This supports later checks and comparisons at the same locations under different operating conditions.
Specify a 3D flow measurement system by identifying the required parameters, measurement locations, and sampling method. WINDTUNER can develop a setup around those needs, combining probe customization and calibration, pressure acquisition, motion control, and measurement and control software. Clear equipment roles and correct links between data and position make the 3D flow measurement system useful for examining flow distributions in development tests.

Results from several points should be traceable to their coordinates and test conditions. Pressure curves or velocity readings without position information are difficult to use for examining a test-section distribution. Keep the necessary probe, calibration, and acquisition settings with the results. This supports later checks and comparisons at the same locations under different operating conditions.
Specify a 3D flow measurement system by identifying the required parameters, measurement locations, and sampling method. WINDTUNER can develop a setup around those needs, combining probe customization and calibration, pressure acquisition, motion control, and measurement and control software. Clear equipment roles and correct links between data and position make the 3D flow measurement system useful for examining flow distributions in development tests.